JNL-600B thermal conductivity analyzer
JNL-600B thermal conductivity analyzer adopts imported thermal conductivity sensor, which is packaged in specific environment and combined with advanced MCU technology to develop a new intelligent industrial gas analyzer. It is suitable for on-line measurement of hydrogen, carbon dioxide, argon and helium in various atmospheres.
Product features
▌ the original imported thermal conductivity sensor is adopted, and the drift is very small;
▌ single point calibration can meet the measurement accuracy of the whole measuring range;
▌ friendly man-machine dialogue menu, easy to operate;
▌ with microprocessor as the core, it has the characteristics of good stability, high reliability and long calibration cycle;
▌ high precision automatic temperature compensation system to eliminate the influence of ambient temperature;
▌ advanced calibration function, user standard gas online calibration;
▌ suitable for measuring helium, hydrogen, argon and carbon dioxide;
▌ the upper and lower limit alarm points can be set arbitrarily in the full range.
Ordering instructions (please indicate when ordering)
▌ instrument measurement range
▌ measured gas pressure: positive pressure, micro positive pressure or micro negative pressure
▌ main components, physical impurities, sulfides, etc. of the tested gas
Application area
It is widely used in petrochemical industry, cryogenic air separation, PSA nitrogen purification unit, high purity nitrogen, high purity argon, helium, argon, carbon dioxide and other industrial gases.
Technical parameter
▌ measurement principle: thermal conductivity
▌ measuring medium: H2 / CO2 / Ar / SO2 / he
▌ measurement range: 0-100% range can be customized
▌ resolution: 0.01%
▌ allowable error: ± 1% FS
▌ repeatability: ≤± 1% F.S
▌ stability: zero drift ≤± 1% F.S
▌ range drift: ≤± 1% F.S
▌ response time: T90 ≤ 30s
▌ sensor life: more than 2 years
▌ sample gas flow: 400 ± 50ml / min
▌ working power supply: 100-240V 50 / 60Hz
▌ power: 25VA
▌ sample gas pressure: 0.05Mpa ~ 0.25MPa (relative pressure)
▌ outlet pressure: normal pressure
▌ sample gas temperature: 0-50 ℃
▌ ambient temperature: - 10 ℃ ~ + 45 ℃
▌ ambient humidity: ≤ 90% RH
▌ output signal: 4-20mA / 0-5V (optional)
▌ communication mode: RS232 (standard configuration) / RS485 (optional)
▌ alarm output: 1 set, passive contact, 0.2A
▌ instrument weight: 2kg
▌ boundary dimension: 253mm × 140mm × 338MM (w × h × d)
▌ opening size: 210mm × 134mm (w × h)
▌ sample gas interface: Φ 6 stainless steel ferrule connector (hard pipe or hose)