JNL-550 constant oxygen analyzer

Short Description:


Product Detail

FAQ

Product Tags

JNL-550 constant oxygen analyzer

JNL-550 constant oxygen analyzer adopts imported fuel cell sensor and advanced MCU technology to develop a new intelligent industrial gas analyzer. It has the characteristics of high precision, long life, good stability and repeatability, and is suitable for on-line measurement of constant oxygen concentration in various atmosphere environments.

Product features  

▌ original imported fuel cell sensor is adopted, with minimal drift;

▌ single point calibration can meet the measurement accuracy of the whole measuring range;

▌ friendly man-machine dialogue menu, easy to operate;

▌ with microprocessor as the core, it has the characteristics of good stability, high reliability and long calibration cycle;

▌ high precision automatic temperature compensation system to eliminate the influence of ambient temperature;

▌ advanced calibration function, user standard gas online calibration;

▌ suitable for the measurement of constant oxygen in nitrogen, hydrogen, argon and reducing gas;

▌ the upper and lower limit alarm points can be set arbitrarily in the full range.

Ordering instructions (please indicate when ordering)

▌ instrument measurement range

▌ measured gas pressure: positive pressure, micro positive pressure or micro negative pressure

▌ main components, physical impurities, sulfides, etc. of the tested gas

Application area

It is widely used in petrochemical industry, cryogenic air separation, PSA nitrogen production, food packaging, chemical smelting (oxygen enriched combustion), gas process control and detection.

Technical parameter

▌ measurement principle: fuel cell

▌ measurement range: 0-1%, 0-5%, 0-25%, 0-30%, 0-40, 0-50% O2 (optional range)

▌ resolution: 0.01%

▌ allowable error: ± 1% FS (0 ~ 5%)

▌ repeatability: ≤± 1% F.S

▌ range drift: ≤± 1% F.S

▌ response time: T90 ≤ 20s

▌ sensor life: more than 2 years

▌ sample gas flow: 400 ± 50ml / min

▌ working power supply: 100-240V 50 / 60Hz

▌ power: 25VA

▌ sample gas pressure: 0.05Mpa ~ 0.25MPa (relative pressure)

▌ outlet pressure: normal pressure

▌ sample gas temperature: 0-50 ℃

▌ ambient temperature: - 10 ℃ ~ + 45 ℃

▌ ambient humidity: ≤ 90% RH

▌ output signal: 4-20mA / 0-5V (optional)

▌ communication mode: RS232 (standard configuration) / RS485 (optional)

▌ alarm output: 1 set, passive contact, 0.2A

▌ instrument weight: 2kg

▌ boundary dimension: 190mm × 110mm × 235mm (w × h × d)

▌ opening size: 170mm × 90mm (w × h)

▌ sample gas interface: Φ 6 stainless steel ferrule connector (hard pipe or hose)