JNL-261 infrared analyzer

Short Description:


Product Detail

FAQ

Product Tags

JNL-261 infrared analyzer

JNL-261 uses infrared ray for gas analysis. It is based on the concentration of the components to be analyzed, the absorbed radiation energy is different, the remaining radiation energy makes the temperature in the detector rise differently, and the pressure on both sides of the moving film is different, thus generating an electrical signal of the capacitance detector. In this way, the concentration of the components to be analyzed can be measured.

Product features  

▌ Chinese and English menu switching function, intuitive and convenient operation;

▌ built in sensor protection device and temperature compensation sensor ensure the service life of the sensor and reduce the impact of sample gas temperature and environment changes on the measurement accuracy;

▌ data automatic storage function, users can look up historical data locally at any time; embedded installation, easy installation and maintenance.

▌ long calibration interval, high precision, stability and reliability;

▌ it has good selectivity for the gas to be measured;

▌ the original infrared spectroscopic sensor is adopted, which has the characteristics of fast response, high precision, small drift and long calibration period;

▌ the analyzer comes with standard RS232 (default) or RS485 communication port, which can realize two-way communication with computer.

Ordering instructions (please indicate when ordering)

▌ instrument measurement range

▌ measured gas pressure: positive pressure, micro positive pressure or micro negative pressure

▌ main components, physical impurities, sulfides, etc. of the tested gas

Application area

It is widely used in petrochemical industry, power plant and other process control detection, cryogenic air separation, infant incubator, experimental box, gas detection in food production process, biological experimental process detection, etc.

Technical parameter

▌ measurement principle: Infrared

▌ measuring medium: Co / CO2 / CH4 / CH / SO2 / NOx / NH3, etc

▌ measurement range: 0-1000ppm / 100% (optional range)

▌ allowable error: ≤± 2% F.S

▌ repeatability: ≤± 1% F.S

▌ stability: zero drift ≤± 1% F.S

▌ range drift: ≤± 1% F.S

▌ response time: T90 ≤ 30s

▌ sensor life: more than 2 years (under normal use conditions)

▌ sample gas flow rate: 400-800ml / min

▌ working power supply: 170-240v 50 / 60Hz

▌ power: 35va

▌ sample gas pressure: 0.05Mpa ~ 0.35Mpa (relative pressure)

▌ outlet pressure: normal pressure

▌ sample gas temperature: 0-50 ℃

▌ ambient temperature: - 10 ℃ ~ + 45 ℃

▌ ambient humidity: ≤ 90% RH

▌ output signal: 4-20mA / 0-5V (optional)

▌ communication mode: RS232 (standard configuration) / RS485 (optional)

▌ alarm output: 1 set, passive contact, 0.2A

▌ weight: 6kg

▌ boundary dimension: 483mm × 137mm × 350mm (w × h × d)

▌ opening size: 445mm × 135mm (w × h) 3U (4U optional)

▌ sample gas interface: Φ 6 stainless steel ferrule connector (hard pipe or hose)