CFL compressed air air-cooled cooler
After the air-cooled high-efficiency air cooler is placed in the compressor, the high-temperature gas produced by the compressor is cooled to below 45 ℃; a large amount of water in the compressed air is removed and discharged from the machine to meet the use conditions of the rear equipment. This series of products are suitable for a wide range of temperature, small volume, convenient installation, low operation cost, long service life, especially suitable for water free, water shortage and mobile users.
Technical Indicators
Working pressure: 0.2-1.0mpa (1.0-3.0mpa can be provided)
Inlet temperature: ≤ 160 ℃
Outlet temperature: ≤ 45 ℃
Ambient temperature: ≤ 35 ℃
Pressure drop: ≤ 0.02MPa
Technical Parameters
Parameter / model | CFL-1F | CFL-2F | CFL-3F | CFL-6F | CFL-10F | CFL-12F | CFL-16F | CFL-20F | CFL-40F | CFL-60F | CFL-80F | |
Air handling capacity (N㎥/min) | 1.2 | 2.4 | 3.8 | 6.5 | 10.7 | 13 | 16.9 | 23 | 45 | 65 | 85 | |
Inlet and outlet diameter DN(mm) | 25 | 25 | 32 | 40 | 50 | 50 | 65 | 65 | 100 | 125 | 150 | |
Power Supply V/Hz |
220/50 |
|||||||||||
Installed power KW | 70 | 90 | 90 | 360 | 360 | 360 | 540 | 540 | 540 | 720 | 720 | |
External dimension(mm) | Length | 700 | 800 | 800 | 1130 | 1750 | 1750 | 1750 | 1750 | 1852 | 1600 | 1600 |
Width | 350 | 400 | 400 | 400 | 400 | 400 | 450 | 450 | 500 | 500 | 600 | |
Height | 600 | 600 | 650 | 700 | 720 | 720 | 750 | 750 | 800 | 1763 | 1763 | |
Equipment weight kg | 50 | 55 | 75 | 135 | 170 | 175 | 215 | 235 | 315 | 450 | 495 |