CPN-H hydrogenated nitrogen purification equipment
The purification process of the combination of two high efficiency catalysts was adopted. Hydrodeoxygenation is carried out at room temperature, and then excess hydrogen is removed (when hydrogen is required). Water and impurities are removed by purification process to obtain high-purity nitrogen.
Technical features
◎Automatic control of the amount of hydrogenation, high degree of automation, safety and reliability.
◎High efficiency catalyst, advanced technology and stable performance.
◎Adopt safe and reliable control elements to ensure reliable operation.
◎Intelligent interlock venting and various fault alarms enable users to find and solve problems in time.
◎Deoxidation at room temperature, no activation, wide range of deoxidization.
Technical indicators
Nitrogen output: 10-20000N ㎥ / h
Nitrogen purity: ≥ 99.9995%
Nitrogen content: 1-1000ppm
Oxygen content: ≤ 5ppm
Dew point: ≤ – 60 ℃
Technical parameters of CPN-H nitrogen purification equipment
Model and specification |
CPN-10H |
CPN-20H |
CPN-40H |
CPN-60H |
CPN-100H |
CPN-100H |
CPN-150H |
CPN-200H |
CPN-300H |
CPN-400H |
CPN-500H |
|
Rated treatment capacity(N㎥/h) |
11 |
22 |
44 |
66 |
110 |
110 |
165 |
220 |
330 |
440 |
550 |
|
Rated nitrogen production(N㎥/h) |
10 |
20 |
40 |
60 |
100 |
100 |
150 |
200 |
300 |
400 |
500 |
|
Power Supply V/HZ |
380/50 |
|||||||||||
Installed power(kw) |
1 |
1.8 |
3.4 |
5.2 |
8.4 |
15 |
12.6 |
16.4 |
16.4 |
22.6 |
42 |
|
Nitrogen consumption(N㎥/h) |
0.15 |
0.3 |
0.45 |
0.7 |
1.2 |
7.2 |
1.7 |
2.3 |
2.3 |
4.5 |
5.6 |
|
Cooling water(t/h) |
0.2 |
0.4 |
0.8 |
1.2 |
2.0 |
160 |
3.0 |
4.0 |
6.0 |
8.0 |
10.0 |
Note 1. The data listed in this table are based on 20 ℃ ambient temperature, 0 m elevation, 32 ℃ cooling water temperature, and 99.5% purity of imported nitrogen.